Simpson F451320 Panel Meter

Vendor: TEquipment
Vendor SKU: F451320
Manufacturer: Simpson
MPN: Simpson F451320
Simpson F451320 Panel Meter
  • 4-1/2, 120VAC, 2VAC
  • 1/8 DIN Indicator
  • 3-1/2 or 4-1/2 digit bright red LED display
  • Front panel pops off for easy decimal point setting and display scaling
  • Only 3.12” (79mm) required behind panel

The Falcon Series digital indicators are premium quality 1/8 DIN meters for industrial applications. All Falcon units feature jumper-selectable decimal point (internal and on the connector for remote decimal point) and display scaling, providing wide application flexibility. In addition, most signal input ranges are easy to change with jumpers on the main board. The Falcon has a 0.56” bright red LED display for high visibility.

Compactly designed for applications requiring minimal rear panel depth, the Falcon fits a standard 1/8 DIN panel cutout (91.9mm x 45mm) and requires less than 3" behind the panel. A screw terminal connector is a standard feature for easy wiring of the power supply and signal input connections.

Mounting Requirements

The Falcon series 1/8 DIN indicators require a panel cutout of 1.77" (45mm) high by 3.62" (91.9mm) wide. To install the Falcon into a panel cutout, remove the clips from the side of the meter. Slide the meter through your panel cutout, then slide the mounting clips back on the meter. Press evenly to ensure a proper fit.

Engineering Label Placement

If replacement of the engineering unit label is required, place the tip of a ball-point pen into the small hole at the base of the engineering label in the bezel. Slide the label up until it pops out. Grasp and remove. Slide the new label half the distance in, then use the ball-point pen to slide it down into place.

General Specifications Display Type 7- segment, red LED Height 0.56" (14.2mm) Decimal User-programmable, internally or on the terminal block Overrange Indication Most significant digit ="1" other digits blank Polarity Automatic, with "-" indication, "+" indication implied Power Requirements AC Voltages 120 or 220VAC, ±10% 50/60Hz DC Voltages 9-32DCV, ±1% Power Consumption F35: 3VA, F45: 2VA Isolation 250V RMS MAX Accuracy @25°C F45 DC Process/Voltage ±0.02% of reading ± 1 count F35 DC Process/Voltage ±0.1% of reading ± 1 count F45 DC Current ±0.05% of reading ±1 count 2A ± 5 counts, 5A ± 5 counts F35 DC Current ±0.1% of reading ± 1 count 2A ± 5 counts, 5A ± 5 counts F45 AC Voltage/Current ±0.5% of reading ± 35 counts F35 AC Voltage/Current * ±1% of reading ± 5 counts (50Hz-100Hz) * For TRMS (45 Hz to 1KHz) Environmental Operating Temperature 0 to 55°C Storage Temperature -10 to 60°C Relative Humidity 0 to 85% non-condensing Warm-up Time Less than 15 minutes Noise Rejection NMRR F35=50dB, 50/60Hz; F45=60dB, 50/60Hz CMRR (w/1K'Ω unbalanced @ 60Hz) 90dB min. A to D Conversion Technique Dual slope integration Rate F35=3 samples per second, nominal; F45=2.5 samples per second, nominal Mechanical Bezel 3.78" x 1.89" x .51" Depth 2.94" Panel Cutout 3.62" X 1.77" Case Material 94V-1, UL rated Noryl® Weight 9.0oz (255.1g) Temperature Coefficient F35 AC/TRMS (Voltage/Current) (±0.1% of input ± 0.5 count)/°C F35 DC (Voltage/Current/Process) (±0.01% of input ± 0.05 count)/°C F45 AC (Voltage/Current) (±0.05% of input ± 0.5 count)/°C F45 DC Current (±0.01% of input ± 0.1 count)/°C F45 DC (Voltage/Process) (±0.05% of input ± 0.1 count)/°C F45 Temperature Meters Display Type 7- segment, red LED Height 0.56" (14.2mm) Decimal Point Jumper-selectable 2-position (corresponding to resolution desired) Overrange indication Most significant digit = "1"; other digits blank Polarity Automatic, with "-" indication, "+| indication implied Power Requirements AC Voltages 120 or 220VAC, ±10% 50/60Hz DC Voltages 9-32 DCV, ±1% Power Consumption 3VA Environmental Operating Temperature 0 to 55°C Storage Temperature -10 to 60°C Relative Humidity 0 to 85% non-condensing Warm-up Time Less than 20 minutes Inputs Thermocouple J, K, E, T, R, and S RTD Platinum 100 (.00385 alpha), 2, 3 or 4 wire Millivolt ±84mV reading of uncompensated mV Input Impedance 7MΩ(typical) Conversion Rate 2-1/2 times per second Open Thermocouple Detection -1 on display, -40nA bias on thermocouple Temperature Sensor Type Temperature Range Accuracy Resolution E -200 to 1000°C ±0.1% of rdg ± 1°C
±0.1% of rdg ± 1.8°F 0.1 or 1 Degree
User Selectable -328 to 1832°F J -200 to 1200°C -328 to 2192°F K -200 to 1372°C -328 to 2501°F T -200 to 400°C -328 to 752°F RTD Pt 100 -200 to 850°C -328 to 1562°F R,S -50 to 1768°C 1 Degree Automatic -58 to 3214°F Voltage Range ±.02% of rdg ± 1 count 0.01 mV ±84.00mV Voltage Range ±.02% of rdg ± 1 count 0.001mV -19.999mV to +84.000mV Inputs DC Voltage Range F35 F45 Max Input (Unfused) Resolution Input Impedance Resolution Input Impedance 200mV 100µV >100MEG 10µV >100MEG 100V 2V 1mV >10MEG 10µV >100MEG 250V 20V 10mV >100MEG 1mV >9.9MEG 250V 200V 100mV >9.9MEG 10mV >9.8MEG 250V AC TRMS Voltage Range F35 F45 Max Input (Unfused) Resolution Input Impedance Resolution Input Impedance 200mV 100µV >100MEG 10µV >100MEG 100V 2V 1mV >1MEG 100µV >1MEG 250V 20V 10mV >10MEG 1mV >1MEG 250V 200V 100mV >9.9MEG 10mV >1MEG 250V DC / AC TRMS Current Range Resolution Voltage Drop Max Input (Unfused) F35 F45 200µA 100µA 10µA 200mV 10 mA 2mA 1µA 100µA 40mA 20mA 10µA 1µA 100mA 200mA 100µA 10µA 500mA 2A 1mA 100µA 2.2A 5A 10mA 1mA 5.2A DC Process Range F35 F45 Max Input (Unfused) Resolution Input Impedance Resolution Input Impedance 4 to 20mA 0.1% 10 Ohms .01 % 10 Ohms 500mV 1 to 5Vdc 0.1% >10MEG .01 % >9.9MEG 10V 0 to 10Vdc 0.1% >10MEG .01 % >9.9MEG 10V † Not available for use with frequency meters
* Only available with F35
** Only available with F45

Specifications

Display Type Digital
Mounting Type Panel
Size Rectangular 1/8 DIN
Type (panel Meter ) Digital
Style (panel Meter) Rectangular/Square
Number Of Inputs (panel Meters) Single
Mounting (panel Meter) Panel Mount
Input (panel Meters) Voltage
Size-face Width Other
Process Output No
Control / Alarm Setpoints No
Water Proof No
Splash Proof No
Relay Output No
Country Of Origin United States